推荐同事 机构合作 中文 繁體中文 English 한국어 日本語 Português Español

美国ACCDON公司旗下品牌

021-33361733,021-33632861

chinasupport@letpub.com

登录 注册 新注册优惠

D Hutton - Plastic Surgical Nursing, 2011 - journals.lww.com
In the first part of the series titled “Emergency Preparedness in the OR—Malignant
Hyperthermia,” the reader was introduced to the current guidelines and research regarding this
potentially lethal condition. In Part II of the series, the reader will be introduced to 2 case ...
Related articles - All 3 versions
PA Friedman… - Cardiac Electrophysiology, 2011 - Springer
... Why is VT misdiagnosed as sinus tachycardia? Case Discussion ... Sinus tachycardia is diagnosed
and VT therapy is withheld if both the R–R and P–R intervals are within the “expected” range.
Premature ventricular complexes increase the expected range of R–R intervals. ...
Related articles
RT Ho, M Ortman, PJ Mather… - Heart Rhythm, 2011 - heartrhythmjournal.com
« PreviousNext »Heart Rhythm Volume 8, Issue 5 , Pages 781-783, May 2011.
Inappropriate sinus tachycardia in a transplanted heart—Further insights into
pathogenesis. Reginald T. Ho, MD: Affiliations. Address reprint requests ...
Cached - All 3 versions
AK Malik, CK Ching, R Liew, DTT Chong… - Europace, 2011 - Eur Heart Rhythm Assoc
During electrophysiological evaluation, a narrow complex tachycardia (cycle length of 393
ms) was easily induced by programmed atrial stimulation. The surface electrocardiogram
(ECG) P wave morphology during tachycardia was similar to sinus rhythm. The atrial ...
S Park, DG Kim, GY Suh, WJ Park, SH Jang… - Journal of Critical …, 2011 - Elsevier
Among the 522 patients enrolled, the average mean HR was 96.1 ± 18.4 beats/min. Fifty-two
(10.0%) patients met the criteria for NOPST; pneumonia, delirium, septic shock, acute respiratory
distress syndrome, catheter-related infections, and mechanical ventilator–related ...
Related articles - All 3 versions
D Hutton - Plastic Surgical Nursing, 2011 - journals.lww.com
In the first part of the series titled “Emergency Preparedness in the OR—Malignant
Hyperthermia,” the reader was introduced to the current guidelines and research regarding this
potentially lethal condition. In Part II of the series, the reader will be introduced to 2 case ...
Related articles - All 3 versions
PA Friedman… - Cardiac Electrophysiology, 2011 - Springer
... Why is VT misdiagnosed as sinus tachycardia? Case Discussion ... Sinus tachycardia is diagnosed
and VT therapy is withheld if both the R–R and P–R intervals are within the “expected” range.
Premature ventricular complexes increase the expected range of R–R intervals. ...
Related articles
RT Ho, M Ortman, PJ Mather… - Heart Rhythm, 2011 - heartrhythmjournal.com
« PreviousNext »Heart Rhythm Volume 8, Issue 5 , Pages 781-783, May 2011.
Inappropriate sinus tachycardia in a transplanted heart—Further insights into
pathogenesis. Reginald T. Ho, MD: Affiliations. Address reprint requests ...
Cached - All 3 versions
AK Malik, CK Ching, R Liew, DTT Chong… - Europace, 2011 - Eur Heart Rhythm Assoc
During electrophysiological evaluation, a narrow complex tachycardia (cycle length of 393
ms) was easily induced by programmed atrial stimulation. The surface electrocardiogram
(ECG) P wave morphology during tachycardia was similar to sinus rhythm. The atrial ...
S Park, DG Kim, GY Suh, WJ Park, SH Jang… - Journal of Critical …, 2011 - Elsevier
Among the 522 patients enrolled, the average mean HR was 96.1 ± 18.4 beats/min. Fifty-two
(10.0%) patients met the criteria for NOPST; pneumonia, delirium, septic shock, acute respiratory
distress syndrome, catheter-related infections, and mechanical ventilator–related ...
Related articles - All 3 versions

联系我们 | 站点地图 | 友情链接 | 授权代理商 | 加入我们

© 2010-2024 中国: LetPub上海分公司    网站备案号:沪ICP备10217908号-1    沪公网安备号:31010402006960

增值电信业务经营许可证:沪B2-20211595

礼翰商务信息咨询(上海)有限公司      办公地址:上海市徐汇区漕溪北路88号圣爱大厦1803室

United States: Tel: 1-781-202-9968 Address: 400 5th Ave, Suite 530, Waltham, Massachusetts 02451